Categories of twisted pair cabling systems



Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   

DEFINITION - ANSI/EIA (American National Standards Institute/Electronic Industries Association) Standard 568 is one of several standards that specify "categories" (the singular is commonly referred to as "CAT") of twisted pair cabling systems, such as wires, junctions, and connectors.

The standards categories:
Category Maximum data rate Usual application
CAT 1 (de facto name, never a standard)
Up to 1 Mbps (1 MHz)

analog voice (POTS)
Basic Rate Interface in ISDN
Doorbell wiring

CAT 2 (de facto name, never a standard) 4 Mbps

Mainly used in the IBM cabling system for Token Ring networks

CAT 3 16 Mbps

Voice (analog most popular implementation)
10BASE-T Ethernet.

CAT 4 20 Mbps

Used in 16 Mbps Token Ring.
Otherwise not used much.

Was only a standard briefly and never widely installed.

CAT 5

100 MHz

100 Mbps TPDDI
155 Mbps
ATM.
No longer supported; replaced by 5E.

10/100BASE-T
4/16MBps Token Ring
Analog Voice
CAT 5E 100 MHz

100 Mbps TPDDI
155 Mbps
ATM
Gigabit Ethernet.
Offers better
near-end crosstalk than CAT 5

CAT 6 Up to 250 MHz Minimum cabling for data centers in TIA-942.
Quickly replacing category 5e.
CAT 6E Up to 500 MHz
(field-tested to 500 MHz)

Support for 10 Gigabit Ethernet (10GBASE-T.) May be either shielded (STP, ScTP, S/FTP) or unshielded (UTP). This standard published in Feb. 2008.
Minimum for Data Centers in ISO data center standard.

CAT 7
(ISO Class F)

600 MHz
1.2
GHz in pairs with Siemon connector

 

Full-motion video
Teleradiology
Government and manufacturing environments
Fully Shielded (S/FTP) system using non-RJ45 connectors but backwards compatible with hybrid cords.

Until February 2008, the only standard (published in 2002) to support 10GBASE-T for a full 100m.

Cabling systems are categorized in terms of the data rates that they can sustain effectively. The specifications describe the cable material as well as the types of connectors and junction blocks to be used in order to conform to a category. For ISO/IEC standards, the category refers to the cable and class refers to the connector. ISO are international standards and can be followed anywhere in the world. A standard is different than a code in that standards are voluntary and provide a guideline so that all manufacturers have a minimum set of parameters to work with. A code, on the other hand, is law and is enforced through an AHJ (Authority having Jurisdiction). 

While longer connections for Gigabit Ethernet use optical fiber, the goal is to leverage the CAT 5 and CAT 5E twisted-pair wiring most organizations already have in place for connections out to the desktop. (Four pairs of twisted pair are used.) In old split pair configurations, PoE MidSpan can not be used. PoE is supported on 5e or better; however the higher performing cable provides better heat performance with shielded systems better than UTP.

The two most widely-installed categories are CAT 3 (voice) and CAT 5e, traditionally, however with new installations, category 5e for voice and one high speed to support 10GBASE-T for long term usage are the most common. According to a BSRIA study, 78% of all new installations are shielded. While the two cables may look identical, CAT 3 is tested to a lower set of specifications and can cause transmission errors if pushed to faster speeds. CAT 3 cabling is near-end crosstalk-certified for only a 16 MHz signal, while CAT 5 cable must pass a 100 MHz test. CAT 5E replaced CAT 5 in both standards groups.

The CAT 6 specification, published in 2002 (the same time as ISO Category 7/class F), improves on CAT 5E in terms of near-end crosstalk, balance, and bandwidth. According to IEEE, 70% of new installs in 2004 were CAT 6.

Category 7/Class F (ISO/IEC), published in 2002, is a fully shielded system. The shielding provides superior noise immunity and performance. Until February 2008, it was the only published standard to support 10GBASE-T to a full 100m.

CAT 7A/Class FA and Category 6A/Class EA specifications were published in February 2008.

CONTRIBUTORS: Carrie Higbie
LAST UPDATED: 11 Jul 2008

Read more about Categories of twisted pair cabling systems:
- IT Knowledge Exchange offers expert advice on cabling. See answers or ask your own questions.
- Siemon offers a free e-book, '10 Gigabit Network Cabling Basics.' (Registration required.)
- NetworkStuff provides a brief description of CAT 7.
- Siemon offers a white paper, "Facts and Fallacies of Testing Next Generation Cabling."


Do you have something to add to this definition? Let us know.
Send your comments to techterms@whatis.com


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   



DATA CENTER RELATED LINKS

Ads by Google
Wireless UTP Coaxial CCTV
Mikrotik, AP, Router, Antenna, RJ45 Everything for LAN, WAN and Fiber
www.4netonline.com
Cat 5 Cable
Check out these valuable Cat 5 Cable resources
HugeDiscounts.cc/Cat5Cable
Looking for Cat 6 Cables?
Need Cat 6 Cables Facts? We Can Help.
megasearchnew.net/Cat6Cables
Cable Tester
Check Out Cable Tester Solutions From A Trusted Source.
www.myewoss.com
RF Cable Assembly Mfg.
Low cost, excellent quality. Serving customers across America
www.pacificwestamerica.com

RELATED CONTENT
With Cisco's Nexus 7000 switch, IP and Fibre Channel converge
Cisco's new Nexus switch combines IP and Fibre Channel storage on a unified 10 Gigabit Ethernet fabric and claims to reduce data center power...
KVM streamlines remote server management
Managing 3,000 servers is no easy task for business intelligence software company SAS, but Avocent KVM switches and management software have certainly...
Cisco, others roll out InfiniBand gear for HPC apps
Cisco, Mellanox Technologies and Voltaire have all introduced new InfiniBand networking technologies aimed for the growing HPC market.

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
alien crosstalk  (SearchDataCenter.com)
coaxial cable  (SearchDataCenter.com)
Coaxial cable is the kind of copper cable used by cable TV companies between the community antenna and user homes and businesses. (Continued...)




HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides enterprise IT professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective IT purchase decisions and managing their organizations' IT projects - with its network of technology-specific Web sites, events and magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Reprints  |  Site Map




All Rights Reserved, Copyright 2005 - 2008, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts
New!!!
Data Center Job Bank
Find Data Center jobs near you.
Enter Location: (City, State or ZIP)
powered by: